Home     Products     Feedback
 

TECHNICAL DETAILS OF ROTARY AIRLOCK VALVE


 
1. Application                      : To be used for discharging the dust from 
                                           bagfilter /Cyclomax hopper. It should seal 
                                           against loss of air / gas and thus maintain 
                                           the operating pressure in the system.

2. Service Temperature        : 100°C, 250°C, 400°C

3. Differential Pressure         : 1500 mm WG (Theoretical)
    Withstanding Capacity

4. Drive Arrangement           :  1) Chain Drive
                                          2) Direct Drive

5. Type of Rotor                 :  1) Fixed Rotor (C. I.)
                                          2) Adjustable Tip Rotor (Fabricated)

6. Size                              : 1) 8" RAV -  a) Valve Capacity - 3.53 m3/hr at 50% 
                                                              filling efficiency and 20 rpm. 
                                                          b) Overall Dimn. Details : 
                                                              Dia. 222 mm. x325 mm. height.
                                       : 2) 14" RAV -a) Valve Capacity - 26.7 m3/hr at 50% filling
                                                              efficiency and 30 rpm. 
                                                          b) Overall Dimn. Details : 
                                                              Dia. 350 mm. x  525 mm. height.



Designed by : MID  Hosted by : PBD  Promoted by : GID